M2 Manual (5.0E) Page 5 of 8
Operation with D12
INPUT A
OUT A
2-Way
SenseDrive
OUT B
2-Way
AMP B
AMP A
D12 Input/Output routing
2-Way Active mode
Selecting "2-Way Active" and M2 mode enables up to two M2
cabinets to be driven actively by the D12 amplifier.
The input signal is fed to INPUT A, while the input signal is routed
(linked) to INPUT B internally.
IMPORTANT!
To apply SenseDrive for the LF driver of both cabinets they should
be linked together locally and connected to the output A connector
of the D12 amplifier.
Controller settings
For acoustic adjustment the settings CUT and CPL can be selected.
CUT
Set to CUT, a high pass filter with a 110 Hz cut off frequency is
inserted in the controller signal path. The M2 is now configured for
use with d&b active subwoofers.
CPL circuit
Frequency response of CPL circuit
The CPL (Coupling) circuit compensates for coupling effects
between the cabinets when building closely coupled arrays. CPL
begins gradually at 1 kHz, with maximum attenuation below
400 Hz, providing a balanced frequency response when the M2
cabinet is used in arrays of two or more. The function of the CPL
circuit in the D12 amplifier is shown in the diagram opposite and
can be set in dB attenuation values between –9 and 0, or a positive
CPL value which creates an adjustable low frequency boost around
65 Hz (0 to +5 dB).
The following CPL settings correspond to the M2 controller settings
of the A1 and are described in the following section "Operation
with A1 - LFC level control":
0 dB = Floor, +3 dB = Free, –3 dB = Pair